Product Details

Presentation

from £211.39
Quick Overview

A powerful stimulus delivery and experimental control program for neuroscience.

Presentation®

A precise and powerful stimulus delivery and experimental control program for neuroscience. It runs on any Windows PC and delivers auditory, visual and multimodal stimuli with sub-millisecond temporal precision. Presentation is powerful enough to handle almost any behavioral, psychological or physiological experiment using fMRI, ERP, MEG, psychophysics, eye movements, single neuron recording, reaction time measures, other performance measures and more.  Presentation is the world's most popular experimental control software with 78139 registrations and 174709 downloads, and counting.

Presentation:

  • runs on Windows XP/Vista/7/8
  • is optimized for behavioral, psychological and physiological experiments using fMRI, ERP, MEG, single neuron recording, reaction time measures and other performance measures
  • is built for precise stimulus delivery and accurate event logging
  • delivers 2D visual, 3D visual, and auditory stimuli separately or simultaneously
  • delivers compressed video with precise frame control
  • monitors responses on a variety of devices
  • interfaces with external hardware
  • is programmable
  • verifies time measurements for all events
  • is extensible
  • Speech recognition
  • Kinect interface
  • Library of Teaching Experiments
     

Licensing Overview:

A Presentation License allows the software to be run on a specific number of computers for a specified period of time. We use the term "activation" to refer to the software running on one computer: to run the software, you must first "activate" the software with a code, key or web activation. The activations on a license must be used by people at the same institution.

A Presentation License is not version specific, so your license may be used to run any version of Presentation you wish. In addition, different versions of Presentation may coexist on the same computer. You may download a newer version, and it will not affect your use of the previous version.
 

For further information or a Quote contact sales@psychologysoftwaredistribution.com
or telephone: +44 (0)1347 878041

To obtain a Quote we will need the following information:

  • Number of Computers (Activations)

  • Duration of Licence (1, 2 or 3 years)

  • Type of Activation (Code, Key or Web)


The following is a summary of Presentation's general support for different classes of devices:

Keyboards, Mice:  Generally all standard keyboards and mice will work with Presentation, both for button press responses, and for axis positions.

Joysticks, Game Controllers:  Presentation can access any DirectX compatible device. This includes almost all commercial game controllers and joysticks. You may use both button press responses and axis positions.

Touch Screens:  Touch screen events will generally appear as mouse clicks within Presentation. Presentation also has a special mode that should provide the touch location for most touch screens.

Auditory responses:  Presentation can monitor an auditory signal from a microphone and generate response events using a volume thresholding feature. You may also record the interval after each response to disk.

Standard serial port button devices:  Button response devices using the standard serial port which send either unique codes for each button event, or the complete state of the device as a single code for each button event, can be used by Presentation.

Parallel digital I/O button devices:  Button response devices which raise or lower the voltage on individual lines of a parallel digital cable can be used in Presentation when connected to either a standard parallel port, or digital I/O cards from National Instruments or Measurement Computing. For some parallel ports, Presentation can use hardware interrupts to handle response events.

fMRI Scanners:  Presentation can synchronize stimuli with port signals from external devices. Presentation's general port I/O facilities are used for this application, which includes standard serial ports, standard parallel ports (including interrupt mode for some ports), National Instruments or Measurement Computing digital I/O cards including pulse-triggered counters.

Stimulators:  Presentation's general port I/O facilities can be used to control some external devices. Port output can be produced on standard serial ports, standard parallel ports, digital output on National Instruments or Measurement Computing digital I/O cards, or analog output (not continuous waveforms) on National Instruments cards.

Eye Trackers:  Presentation provides a general interface for controlling and accessing real time eye data from eye tracking systems. This interface must be implemented for each eye tracker in the form of a Presentation Eye Tracker Extension. To check the availability of an extension for you eye tracker, see the other tabs on this page, or contact your eye tracker manufacturer. In the event that no extension is available, some tracker data might be available using Presentation's general port I/O facilities, depending on the eye tracker.

Physiological Recording Systems:  Presentation's general port I/O facilities can be used to send event information to physiological recording systems so that it can be embedded in the recorded data.

Matlab:  Presentation provides an interface to Matlab which allows arbitrary execution of Matlab commands, and import of data into Presentation. Any devices supported within Matlab can potentially be used within Presentation this way.

External Software:  Presentation provides a "plug-in" facility for interfacing Presentation to external software. These Presentation Extensions can be written by anyone and can be used to interface with devices not directly supported by Presentation. Details can be found in the Presentation documentation, and sample code is contained in the Presentation SDK available from the Presentation download page.
 

For further information or a Quote contact sales@psychologysoftwaredistribution.com
or telephone: +44 (0)1347 878041


To obtain a Quote we will need the following information:

  • Number of Computers (Activations)
  • Duration of Licence (1, 2 or 3 years)
  • Type of Activation (Code, Key or Web)

Windows XP/Vista/7/8

Presentation

One Year - 1 Code Activation (Ed) £ 211.39
One Year - 2 Code Activations (Ed) £ 338.23
One Year - 3 Code Activations (Ed) £ 465.06
One Year - 4 Code Activations (Ed) £ 576.53
One Year - 5 Code Activations (Ed) £ 668.77
One Year - 10+ Code Activations (Ed) £ 101.47
One Year - 1 Key Activation (Ed) £ 338.23
One Year - 2 Key Activations (Ed) £ 576.53
One Year - 3 Key Activations (Ed) £ 761.01
One Year - 4 Key Activations (Ed) £ 914.75
One Year - 5 Key Activations (Ed) £ 1014.68
One Year - 6+ Key Activations (Ed) £ 202.94
One Year - Student (Ed) £ 76.10
One Year - Mixed Key & Code Activations (Ed)
Specify Quantities and contact us for a quote
£ 0.00
30 Day - Short Duration - 1 Licence Activation
Specify key or code
£ 26.90
90 Day - Short Duration - 1 Licence Activation
Specify key or code
£ 61.50
One Year - 1 Web Experiment Activation £ 768.70
One Year - Additional Web Experiment(s) £ 384.35

All prices exclude VAT and shipping

To order the item(s) above or to request more information, simply add this item to your cart and complete the quote/order form, or contact us by:

  Phone: +44 (0)1347 878041
  Fax: +44 (0)870 622 0136
  Email: sales@psychologysoftwaredistribution.com